{"formats":[{"name":"JSON","format":"json","url":"\/downloads\/2025\/code-json\/40.1-51.19_4.json"},{"name":"Plain Text","format":"text","url":"\/downloads\/2025\/code-text\/40.1-51.19_4.txt"},{"name":"XML","format":"xml","url":"\/downloads\/2025\/code-xml\/40.1-51.19_4.xml"},{"name":"HTML","format":"html","url":"\/downloads\/2025\/code-html\/40.1-51.19_4.html"}],"law_id":66400,"edition_id":1,"section_id":66400,"structure_id":15644,"section_number":"40.1-51.19:4","catch_line":"Operations and maintenance","history":"1999, c. 335; 2000, c. 898.","full_text":"A\n\nA hobby or model boiler must be attended by a person reasonably competent to operate such boiler when in operation. For the purposes of this section, a hobby or model boiler may be considered as not being in operation when all of the following conditions exist:1\n\nThe water level is at least one-third of the water gauge glass;2\n\nThe fire is banked and the draft doors closed or the fire is extinguished; and3\n\nThe boiler pressure is at least twenty pounds per square inch below the lowest safety valve set pressure.B\n\nAll welding performed on hobby or model boilers shall be done by an &#8220;R&#8221; stamp holder in accordance with the inspection code of the National Board of Boiler and Pressure Vessel Inspectors.C\n\nRepairs to longitudinal riveted joints are prohibited.","order_by":null,"text":{"0":{"id":241027,"text":"A hobby or model boiler must be attended by a person reasonably competent to operate such boiler when in operation. For the purposes of this section, a hobby or model boiler may be considered as not being in operation when all of the following conditions exist:","type":"section","prefixes":["A"],"prefix":"A","entire_prefix":"A","prefix_anchor":"A","level":1,"next_prefix":"A1"},"1":{"id":241028,"text":"The water level is at least one-third of the water gauge glass;","type":"section","prefixes":["A","1"],"prefix":"1","entire_prefix":"A1","prefix_anchor":"A1","level":2,"prior_prefix":"A","next_prefix":"A2"},"2":{"id":241029,"text":"The fire is banked and the draft doors closed or the fire is extinguished; and","type":"section","prefixes":["A","2"],"prefix":"2","entire_prefix":"A2","prefix_anchor":"A2","level":2,"prior_prefix":"A1","next_prefix":"A3"},"3":{"id":241030,"text":"The boiler pressure is at least twenty pounds per square inch below the lowest safety valve set pressure.","type":"section","prefixes":["A","3"],"prefix":"3","entire_prefix":"A3","prefix_anchor":"A3","level":2,"prior_prefix":"A2","next_prefix":"B"},"4":{"id":241031,"text":"All welding performed on hobby or model boilers shall be done by an &#8220;R&#8221; stamp holder in accordance with the inspection code of the National Board of Boiler and Pressure Vessel Inspectors.","type":"section","prefixes":["B"],"prefix":"B","entire_prefix":"B","prefix_anchor":"B","level":1,"prior_prefix":"A3","next_prefix":"C"},"5":{"id":241032,"text":"Repairs to longitudinal riveted joints are prohibited.","type":"section","prefixes":["C"],"prefix":"C","entire_prefix":"C","prefix_anchor":"C","level":1,"prior_prefix":"B"}},"ancestry":[{"id":15644,"edition_id":1,"name":"Hobby and Model Boilers","identifier":"2","label":"article","depth":3,"order_by":1,"parent_id":14121,"metadata":{},"date_created":"2026-06-26 03:57:19","date_modified":"2026-06-26 03:57:19","permalink":{"id":220259,"object_type":"structure","relational_id":15644,"identifier":"2","token":"40.1\/3.1\/2","url":"\/40.1\/3.1\/2\/","edition_id":1,"permalink":0,"preferred":1}},{"id":14121,"edition_id":1,"name":"Boiler and Pressure Vessel Safety Act","identifier":"3.1","label":"chapter","depth":2,"order_by":1,"parent_id":12776,"metadata":{},"date_created":"2026-06-26 03:46:56","date_modified":"2026-06-26 03:46:56","permalink":{"id":220175,"object_type":"structure","relational_id":14121,"identifier":"3.1","token":"40.1\/3.1","url":"\/40.1\/3.1\/","edition_id":1,"permalink":0,"preferred":1}},{"id":12776,"edition_id":1,"name":"Labor and Employment","identifier":"40.1","label":"title","depth":1,"order_by":1,"parent_id":null,"metadata":{},"date_created":"2026-06-26 03:43:52","date_modified":"2026-06-26 03:43:52","permalink":{"id":219723,"object_type":"structure","relational_id":12776,"identifier":"40.1","token":"40.1","url":"\/40.1\/","edition_id":1,"permalink":0,"preferred":1}}],"structure_contents":[{"id":77255,"structure_id":15644,"section_number":"40.1-51.19:1","catch_line":"Definitions","url":"\/40.1-51.19_1\/","token":"40.1\/3.1\/2\/40.1-51.19_1","metadata":false},{"id":59794,"structure_id":15644,"section_number":"40.1-51.19:2","catch_line":"Applicability","url":"\/40.1-51.19_2\/","token":"40.1\/3.1\/2\/40.1-51.19_2","metadata":false},{"id":83523,"structure_id":15644,"section_number":"40.1-51.19:3","catch_line":"Inspection and testing","url":"\/40.1-51.19_3\/","token":"40.1\/3.1\/2\/40.1-51.19_3","metadata":false},{"id":66400,"structure_id":15644,"section_number":"40.1-51.19:4","catch_line":"Operations and maintenance","url":"\/40.1-51.19_4\/","token":"40.1\/3.1\/2\/40.1-51.19_4","metadata":false},{"id":79228,"structure_id":15644,"section_number":"40.1-51.19:4.1","catch_line":"Variances","url":"\/40.1-51.19_4.1\/","token":"40.1\/3.1\/2\/40.1-51.19_4.1","metadata":false},{"id":83335,"structure_id":15644,"section_number":"40.1-51.19:5","catch_line":"Civil penalty","url":"\/40.1-51.19_5\/","token":"40.1\/3.1\/2\/40.1-51.19_5","metadata":false}],"previous_section":{"id":83523,"structure_id":15644,"section_number":"40.1-51.19:3","catch_line":"Inspection and testing","url":"\/40.1-51.19_3\/","token":"40.1\/3.1\/2\/40.1-51.19_3","metadata":false},"next_section":{"id":79228,"structure_id":15644,"section_number":"40.1-51.19:4.1","catch_line":"Variances","url":"\/40.1-51.19_4.1\/","token":"40.1\/3.1\/2\/40.1-51.19_4.1","metadata":false},"metadata":false,"official_url":"https:\/\/law.lis.virginia.gov\/vacode\/40.1-51.19:4\/","history_text":"<p>This law was first created in 1999. The record of its establishment is cataloged in chapter <a href=\"https:\/\/legacylis.virginia.gov\/cgi-bin\/legp604.exe?991+ful+CHAP0335\">335<\/a> of that year\u2019s edition of \u201cActs of Assembly,\u201d the annual state publication listing all changes made to the Code of Virginia in that year. It has been modified 1 time. Those modifications are cataloged by \u201cThe Acts of Assembly,\u201d a state publication, by year and chapter. Those modifications that can be read on the General Assembly\u2019s website will be linked accordingly. That modification is as follows: in 2000, chapter <a href=\"https:\/\/legacylis.virginia.gov\/cgi-bin\/legp604.exe?001+ful+CHAP0898\">898<\/a>.<\/p>","references":false,"refers_to":false,"permalink":{"id":220273,"object_type":"law","relational_id":66400,"identifier":"40.1-51.19:4","token":"40.1\/3.1\/2\/40.1-51.19_4","url":"\/40.1-51.19_4\/","edition_id":1,"permalink":0,"preferred":1},"url":"\/40.1-51.19_4\/","token":"40.1\/3.1\/2\/40.1-51.19_4","dublin_core":{"Title":"Operations and maintenance","Type":"Text","Format":"text\/html","Identifier":"\u00a7 40.1-51.19:4","Relation":"Code of Virginia"},"html":"\n\t\t\t\t\t\t<section id=\"A\"><p><span class=\"prefix-number\">A.<\/span> A hobby or <span class=\"dictionary\">model boiler<\/span> must be attended by a person reasonably competent to operate such boiler when in operation. For the purposes of this section, a hobby or <span class=\"dictionary\">model boiler<\/span> may be considered as not being in operation when all of the following conditions exist: <a id=\"paragraph-241027\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/40.1-51.19_4\/#A\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"A1\" class=\"indent-1\"><p><span class=\"prefix-number\">1.<\/span> The water level is at least one-third of the water gauge glass; <a id=\"paragraph-241028\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/40.1-51.19_4\/#A1\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"A2\" class=\"indent-1\"><p><span class=\"prefix-number\">2.<\/span> The fire is banked and the draft doors closed or the fire is extinguished; and <a id=\"paragraph-241029\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/40.1-51.19_4\/#A2\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"A3\" class=\"indent-1\"><p><span class=\"prefix-number\">3.<\/span> The boiler pressure is at least twenty pounds per square inch below the lowest safety valve set pressure. <a id=\"paragraph-241030\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/40.1-51.19_4\/#A3\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"B\"><p><span class=\"prefix-number\">B.<\/span> All welding performed on hobby or <span class=\"dictionary\">model boilers<\/span> shall be done by an &#8220;R&#8221; stamp holder in accordance with the inspection code of the National <span class=\"dictionary\">Board<\/span> of Boiler and Pressure Vessel Inspectors. <a id=\"paragraph-241031\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/40.1-51.19_4\/#B\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"C\"><p><span class=\"prefix-number\">C.<\/span> Repairs to longitudinal riveted joints are prohibited. <a id=\"paragraph-241032\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/40.1-51.19_4\/#C\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>","plain_text":"                                 CODE OF VIRGINIA\n\nOPERATIONS AND MAINTENANCE (\u00a7 40.1-51.19:4)\n\nA. A hobby or model boiler must be attended by a person reasonably competent to\noperate such boiler when in operation. For the purposes of this section, a hobby\nor model boiler may be considered as not being in operation when all of the\nfollowing conditions exist:\n\n   1. The water level is at least one-third of the water gauge glass;\n\n   2. The fire is banked and the draft doors closed or the fire is extinguished;\n   and\n\n   3. The boiler pressure is at least twenty pounds per square inch below the\n   lowest safety valve set pressure.\n\nB. All welding performed on hobby or model boilers shall be done by an\n&#8220;R&#8221; stamp holder in accordance with the inspection code of the\nNational Board of Boiler and Pressure Vessel Inspectors.\n\nC. Repairs to longitudinal riveted joints are prohibited.\n\nHISTORY: 1999, c. 335; 2000, c. 898.","edition":{"id":1,"name":"2025","slug":"2025","date_created":"2026-06-21 22:39:22","date_modified":"2026-06-21 22:39:22","current":1,"order_by":1,"last_import":null}}