{"formats":[{"name":"JSON","format":"json","url":"\/downloads\/2025\/code-json\/45.2-914.json"},{"name":"Plain Text","format":"text","url":"\/downloads\/2025\/code-text\/45.2-914.txt"},{"name":"XML","format":"xml","url":"\/downloads\/2025\/code-xml\/45.2-914.xml"},{"name":"HTML","format":"html","url":"\/downloads\/2025\/code-html\/45.2-914.html"}],"law_id":78270,"edition_id":1,"section_id":78270,"structure_id":16207,"section_number":"45.2-914","catch_line":" Fire precautions","history":"Code 1950, \u00a7 45-85.9; 1954, c. 191; 1966, c. 594, \u00a7 45.1-39; 1978, c. 729; 1994, c. 28, \u00a7 45.1-161.267; 2021, Sp. Sess. I, c. 387.","full_text":"A\n\nAn examination for fire shall be made after every blasting operation.B\n\nNo person shall smoke or use an open flame within 25 feet of any location used to handle or store flammable or combustible liquids or where an arc or flame could cause a fire or explosion.C\n\nAny area surrounding a flammable liquid storage tank or electrical substation or transformer shall be kept free of combustible material for at least 25 feet in every direction. Each such storage tank, substation, or transformer shall be posted with readily visible fire hazard warning signs.D\n\nAny structure or area used for storage of flammable materials shall be constructed of fire resistant material; kept well-ventilated, clean, and orderly; and posted with readily visible fire hazard warning signs.E\n\nEvery fuel line shall be equipped with a shut-off valve at its source. Each such valve shall be readily accessible and maintained in good operating condition.F\n\nEvery battery charging area shall be well-ventilated and posted with warning signs prohibiting smoking or open flames within 25 feet.G\n\nOil, grease, flammable hydraulic fluid, and other flammable materials shall be kept in closed metal containers and separated from other materials so as to not create a fire hazard.H\n\nCombustible materials, grease, lubricants, paints, and other flammable materials and liquids shall not be allowed to accumulate where they could create a fire hazard. Provision shall be made to prevent the accumulation of such material on any equipment, at any storage area, and at any location where the material is used.I\n\nElectric motors, switches, lighting fixtures, and controls shall be protected by dust-tight construction.J\n\nPrecautions shall be taken to ensure that no spark or other hot material results in a fire when welding or cutting. No welding or cutting with an arc or flame shall be done in any excessively dusty atmosphere or location. Firefighting apparatus shall be readily available when welding or cutting is performed.K\n\nPrecautions shall be taken before applying heat, cutting, or welding on any pipe or container that has contained a flammable or combustible material.L\n\nEvery oxygen or acetylene bottle shall be (i) stored in a rack constructed and designated for the storage of such bottles with their caps in place and (ii) secured when not in use. Such bottles shall not be stored near oil, grease, or other flammable material.M\n\nEvery oxygen and acetylene gauge and regulator shall be kept clean and free of oil, grease, and other combustible materials.N\n\nEvery belt conveyor shall be equipped with a control switch to automatically stop the driving motor of the conveyor in the event that the belt is stopped by slipping on the driving pulley as a result of breakage or other accident.O\n\nThe area surrounding every main fan installation or other mine opening shall be kept free from grass, weeds, underbrush, and other combustible materials for 25 feet in every direction.P\n\nEvery internal combustion engine, except a diesel engine, shall be shut off prior to fueling.","order_by":null,"text":{"0":{"id":280562,"text":"An examination for fire shall be made after every blasting operation.","type":"section","prefixes":["A"],"prefix":"A","entire_prefix":"A","prefix_anchor":"A","level":1,"next_prefix":"B"},"1":{"id":280563,"text":"No person shall smoke or use an open flame within 25 feet of any location used to handle or store flammable or combustible liquids or where an arc or flame could cause a fire or explosion.","type":"section","prefixes":["B"],"prefix":"B","entire_prefix":"B","prefix_anchor":"B","level":1,"prior_prefix":"A","next_prefix":"C"},"2":{"id":280564,"text":"Any area surrounding a flammable liquid storage tank or electrical substation or transformer shall be kept free of combustible material for at least 25 feet in every direction. Each such storage tank, substation, or transformer shall be posted with readily visible fire hazard warning signs.","type":"section","prefixes":["C"],"prefix":"C","entire_prefix":"C","prefix_anchor":"C","level":1,"prior_prefix":"B","next_prefix":"D"},"3":{"id":280565,"text":"Any structure or area used for storage of flammable materials shall be constructed of fire resistant material; kept well-ventilated, clean, and orderly; and posted with readily visible fire hazard warning signs.","type":"section","prefixes":["D"],"prefix":"D","entire_prefix":"D","prefix_anchor":"D","level":1,"prior_prefix":"C","next_prefix":"E"},"4":{"id":280566,"text":"Every fuel line shall be equipped with a shut-off valve at its source. Each such valve shall be readily accessible and maintained in good operating condition.","type":"section","prefixes":["E"],"prefix":"E","entire_prefix":"E","prefix_anchor":"E","level":1,"prior_prefix":"D","next_prefix":"F"},"5":{"id":280567,"text":"Every battery charging area shall be well-ventilated and posted with warning signs prohibiting smoking or open flames within 25 feet.","type":"section","prefixes":["F"],"prefix":"F","entire_prefix":"F","prefix_anchor":"F","level":1,"prior_prefix":"E","next_prefix":"G"},"6":{"id":280568,"text":"Oil, grease, flammable hydraulic fluid, and other flammable materials shall be kept in closed metal containers and separated from other materials so as to not create a fire hazard.","type":"section","prefixes":["G"],"prefix":"G","entire_prefix":"G","prefix_anchor":"G","level":1,"prior_prefix":"F","next_prefix":"H"},"7":{"id":280569,"text":"Combustible materials, grease, lubricants, paints, and other flammable materials and liquids shall not be allowed to accumulate where they could create a fire hazard. Provision shall be made to prevent the accumulation of such material on any equipment, at any storage area, and at any location where the material is used.","type":"section","prefixes":["H"],"prefix":"H","entire_prefix":"H","prefix_anchor":"H","level":1,"prior_prefix":"G","next_prefix":"I"},"8":{"id":280570,"text":"Electric motors, switches, lighting fixtures, and controls shall be protected by dust-tight construction.","type":"section","prefixes":["I"],"prefix":"I","entire_prefix":"I","prefix_anchor":"I","level":1,"prior_prefix":"H","next_prefix":"J"},"9":{"id":280571,"text":"Precautions shall be taken to ensure that no spark or other hot material results in a fire when welding or cutting. No welding or cutting with an arc or flame shall be done in any excessively dusty atmosphere or location. Firefighting apparatus shall be readily available when welding or cutting is performed.","type":"section","prefixes":["J"],"prefix":"J","entire_prefix":"J","prefix_anchor":"J","level":1,"prior_prefix":"I","next_prefix":"K"},"10":{"id":280572,"text":"Precautions shall be taken before applying heat, cutting, or welding on any pipe or container that has contained a flammable or combustible material.","type":"section","prefixes":["K"],"prefix":"K","entire_prefix":"K","prefix_anchor":"K","level":1,"prior_prefix":"J","next_prefix":"L"},"11":{"id":280573,"text":"Every oxygen or acetylene bottle shall be (i) stored in a rack constructed and designated for the storage of such bottles with their caps in place and (ii) secured when not in use. Such bottles shall not be stored near oil, grease, or other flammable material.","type":"section","prefixes":["L"],"prefix":"L","entire_prefix":"L","prefix_anchor":"L","level":1,"prior_prefix":"K","next_prefix":"M"},"12":{"id":280574,"text":"Every oxygen and acetylene gauge and regulator shall be kept clean and free of oil, grease, and other combustible materials.","type":"section","prefixes":["M"],"prefix":"M","entire_prefix":"M","prefix_anchor":"M","level":1,"prior_prefix":"L","next_prefix":"N"},"13":{"id":280575,"text":"Every belt conveyor shall be equipped with a control switch to automatically stop the driving motor of the conveyor in the event that the belt is stopped by slipping on the driving pulley as a result of breakage or other accident.","type":"section","prefixes":["N"],"prefix":"N","entire_prefix":"N","prefix_anchor":"N","level":1,"prior_prefix":"M","next_prefix":"O"},"14":{"id":280576,"text":"The area surrounding every main fan installation or other mine opening shall be kept free from grass, weeds, underbrush, and other combustible materials for 25 feet in every direction.","type":"section","prefixes":["O"],"prefix":"O","entire_prefix":"O","prefix_anchor":"O","level":1,"prior_prefix":"N","next_prefix":"P"},"15":{"id":280577,"text":"Every internal combustion engine, except a diesel engine, shall be shut off prior to fueling.","type":"section","prefixes":["P"],"prefix":"P","entire_prefix":"P","prefix_anchor":"P","level":1,"prior_prefix":"O"}},"ancestry":[{"id":16207,"edition_id":1,"name":"Fire Prevention and Fire Control","identifier":"5","label":"article","depth":5,"order_by":1,"parent_id":13645,"metadata":{},"date_created":"2026-06-26 04:09:10","date_modified":"2026-06-26 04:09:10","permalink":{"id":224023,"object_type":"structure","relational_id":16207,"identifier":"5","token":"45.2\/II\/C\/9\/5","url":"\/45.2\/II\/C\/9\/5\/","edition_id":1,"permalink":0,"preferred":1}},{"id":13645,"edition_id":1,"name":"Requirements Applicable to Surface Coal Mines","identifier":"9","label":"chapter","depth":4,"order_by":1,"parent_id":13539,"metadata":{},"date_created":"2026-06-26 03:45:27","date_modified":"2026-06-26 03:45:27","permalink":{"id":223921,"object_type":"structure","relational_id":13645,"identifier":"9","token":"45.2\/II\/C\/9","url":"\/45.2\/II\/C\/9\/","edition_id":1,"permalink":0,"preferred":1}},{"id":13539,"edition_id":1,"name":"Surface Coal Mines","identifier":"C","label":"part","depth":3,"order_by":1,"parent_id":12985,"metadata":{},"date_created":"2026-06-26 03:45:10","date_modified":"2026-06-26 03:45:10","permalink":{"id":223695,"object_type":"structure","relational_id":13539,"identifier":"C","token":"45.2\/II\/C","url":"\/45.2\/II\/C\/","edition_id":1,"permalink":0,"preferred":1}},{"id":12985,"edition_id":1,"name":"Coal Mining","identifier":"II","label":"subtitle","depth":2,"order_by":1,"parent_id":12713,"metadata":{},"date_created":"2026-06-26 03:44:06","date_modified":"2026-06-26 03:44:06","permalink":{"id":222647,"object_type":"structure","relational_id":12985,"identifier":"II","token":"45.2\/II","url":"\/45.2\/II\/","edition_id":1,"permalink":0,"preferred":1}},{"id":12713,"edition_id":1,"name":"Mines, Minerals, and Energy","identifier":"45.2","label":"title","depth":1,"order_by":1,"parent_id":null,"metadata":{},"date_created":"2026-06-26 03:43:49","date_modified":"2026-06-26 03:43:49","permalink":{"id":222539,"object_type":"structure","relational_id":12713,"identifier":"45.2","token":"45.2","url":"\/45.2\/","edition_id":1,"permalink":0,"preferred":1}}],"structure_contents":[{"id":79765,"structure_id":16207,"section_number":"45.2-912","catch_line":" Firefighting equipment; duties in case of fire; fire precaution in transportation of mining equipment; fire prevention generally","url":"\/45.2-912\/","token":"45.2\/II\/C\/9\/5\/45.2-912","metadata":false},{"id":64848,"structure_id":16207,"section_number":"45.2-913","catch_line":" Duties in case of fire","url":"\/45.2-913\/","token":"45.2\/II\/C\/9\/5\/45.2-913","metadata":false},{"id":78270,"structure_id":16207,"section_number":"45.2-914","catch_line":" Fire precautions","url":"\/45.2-914\/","token":"45.2\/II\/C\/9\/5\/45.2-914","metadata":false}],"previous_section":{"id":64848,"structure_id":16207,"section_number":"45.2-913","catch_line":" Duties in case of fire","url":"\/45.2-913\/","token":"45.2\/II\/C\/9\/5\/45.2-913","metadata":false},"metadata":false,"official_url":"https:\/\/law.lis.virginia.gov\/vacode\/45.2-914\/","history_text":"<p>The record of this law\u2019s original creation isn\u2019t available online. It has been modified 4 times. Those modifications are cataloged by \u201cThe Acts of Assembly,\u201d a state publication, by year and chapter. Those modifications that can be read on the General Assembly\u2019s website will be linked accordingly. Those modifications are as follows: in 1954, chapter 191; in 1966, chapter 594; in 1978, chapter 729; in 1994, chapter <a href=\"https:\/\/legacylis.virginia.gov\/cgi-bin\/legp604.exe?941+ful+CHAP0028\">28<\/a>.<\/p>","references":false,"refers_to":false,"permalink":{"id":224033,"object_type":"law","relational_id":78270,"identifier":"45.2-914","token":"45.2\/II\/C\/9\/5\/45.2-914","url":"\/45.2-914\/","edition_id":1,"permalink":0,"preferred":1},"url":"\/45.2-914\/","token":"45.2\/II\/C\/9\/5\/45.2-914","dublin_core":{"Title":" Fire precautions","Type":"Text","Format":"text\/html","Identifier":"\u00a7 45.2-914","Relation":"Code of Virginia"},"html":"\n\t\t\t\t\t\t<section id=\"A\"><p><span class=\"prefix-number\">A.<\/span> An examination for fire shall be made after every blasting operation. <a id=\"paragraph-280562\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-914\/#A\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"B\"><p><span class=\"prefix-number\">B.<\/span> No person shall smoke or use an open flame within 25 feet of any location used to handle or store flammable or combustible liquids or where an arc or flame could cause a fire or explosion. <a id=\"paragraph-280563\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-914\/#B\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"C\"><p><span class=\"prefix-number\">C.<\/span> Any area surrounding a flammable liquid storage tank or electrical substation or transformer shall be kept free of combustible <span class=\"dictionary\">material<\/span> for at least 25 feet in every direction. Each such storage tank, substation, or transformer shall be posted with readily visible fire hazard warning signs. <a id=\"paragraph-280564\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-914\/#C\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"D\"><p><span class=\"prefix-number\">D.<\/span> Any structure or area used for storage of flammable <span class=\"dictionary\">materials<\/span> shall be constructed of fire resistant <span class=\"dictionary\">material<\/span>; kept well-ventilated, clean, and orderly; and posted with readily visible fire hazard warning signs. <a id=\"paragraph-280565\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-914\/#D\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"E\"><p><span class=\"prefix-number\">E.<\/span> Every fuel line shall be equipped with a shut-off valve at its source. Each such valve shall be readily accessible and maintained in good operating condition. <a id=\"paragraph-280566\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-914\/#E\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"F\"><p><span class=\"prefix-number\">F.<\/span> Every <span class=\"dictionary\">battery<\/span> charging area shall be well-ventilated and posted with warning signs prohibiting smoking or open flames within 25 feet. <a id=\"paragraph-280567\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-914\/#F\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"G\"><p><span class=\"prefix-number\">G.<\/span> Oil, grease, flammable hydraulic fluid, and other flammable <span class=\"dictionary\">materials<\/span> shall be kept in closed metal containers and separated from other <span class=\"dictionary\">materials<\/span> so as to not create a fire hazard. <a id=\"paragraph-280568\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-914\/#G\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"H\"><p><span class=\"prefix-number\">H.<\/span> Combustible <span class=\"dictionary\">materials<\/span>, grease, lubricants, paints, and other flammable <span class=\"dictionary\">materials<\/span> and liquids shall not be allowed to accumulate where they could create a fire hazard. Provision shall be made to prevent the accumulation of such <span class=\"dictionary\">material<\/span> on any equipment, at any storage area, and at any location where the <span class=\"dictionary\">material<\/span> is used. <a id=\"paragraph-280569\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-914\/#H\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"I\"><p><span class=\"prefix-number\">I.<\/span> Electric motors, switches, lighting fixtures, and controls shall be protected by dust-tight construction. <a id=\"paragraph-280570\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-914\/#I\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"J\"><p><span class=\"prefix-number\">J.<\/span> Precautions shall be taken to ensure that no spark or other hot <span class=\"dictionary\">material<\/span> results in a fire when welding or cutting. No welding or cutting with an arc or flame shall be done in any excessively dusty atmosphere or location. Firefighting apparatus shall be readily available when welding or cutting is performed. <a id=\"paragraph-280571\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-914\/#J\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"K\"><p><span class=\"prefix-number\">K.<\/span> Precautions shall be taken before applying heat, cutting, or welding on any pipe or container that has contained a flammable or combustible <span class=\"dictionary\">material<\/span>. <a id=\"paragraph-280572\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-914\/#K\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"L\"><p><span class=\"prefix-number\">L.<\/span> Every oxygen or acetylene bottle shall be (i) stored in a rack constructed and designated for the storage of such bottles with their caps in place and (ii) secured when not in use. Such bottles shall not be stored near oil, grease, or other flammable <span class=\"dictionary\">material<\/span>. <a id=\"paragraph-280573\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-914\/#L\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"M\"><p><span class=\"prefix-number\">M.<\/span> Every oxygen and acetylene gauge and regulator shall be kept clean and free of oil, grease, and other combustible <span class=\"dictionary\">materials<\/span>. <a id=\"paragraph-280574\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-914\/#M\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"N\"><p><span class=\"prefix-number\">N.<\/span> Every belt conveyor shall be equipped with a control switch to automatically stop the driving motor of the conveyor in the event that the belt is stopped by slipping on the driving pulley as a result of breakage or other accident. <a id=\"paragraph-280575\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-914\/#N\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"O\"><p><span class=\"prefix-number\">O.<\/span> The area surrounding every main fan installation or other mine opening shall be kept free from grass, weeds, underbrush, and other combustible <span class=\"dictionary\">materials<\/span> for 25 feet in every direction. <a id=\"paragraph-280576\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-914\/#O\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"P\"><p><span class=\"prefix-number\">P.<\/span> Every internal combustion engine, except a diesel engine, shall be shut off prior to fueling. <a id=\"paragraph-280577\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-914\/#P\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>","plain_text":"                                 CODE OF VIRGINIA\n\n FIRE PRECAUTIONS (\u00a7 45.2-914)\n\nA. An examination for fire shall be made after every blasting operation.\n\nB. No person shall smoke or use an open flame within 25 feet of any location\nused to handle or store flammable or combustible liquids or where an arc or\nflame could cause a fire or explosion.\n\nC. Any area surrounding a flammable liquid storage tank or electrical substation\nor transformer shall be kept free of combustible material for at least 25 feet\nin every direction. Each such storage tank, substation, or transformer shall be\nposted with readily visible fire hazard warning signs.\n\nD. Any structure or area used for storage of flammable materials shall be\nconstructed of fire resistant material; kept well-ventilated, clean, and\norderly; and posted with readily visible fire hazard warning signs.\n\nE. Every fuel line shall be equipped with a shut-off valve at its source. Each\nsuch valve shall be readily accessible and maintained in good operating\ncondition.\n\nF. Every battery charging area shall be well-ventilated and posted with warning\nsigns prohibiting smoking or open flames within 25 feet.\n\nG. Oil, grease, flammable hydraulic fluid, and other flammable materials shall\nbe kept in closed metal containers and separated from other materials so as to\nnot create a fire hazard.\n\nH. Combustible materials, grease, lubricants, paints, and other flammable\nmaterials and liquids shall not be allowed to accumulate where they could create\na fire hazard. Provision shall be made to prevent the accumulation of such\nmaterial on any equipment, at any storage area, and at any location where the\nmaterial is used.\n\nI. Electric motors, switches, lighting fixtures, and controls shall be protected\nby dust-tight construction.\n\nJ. Precautions shall be taken to ensure that no spark or other hot material\nresults in a fire when welding or cutting. No welding or cutting with an arc or\nflame shall be done in any excessively dusty atmosphere or location.\nFirefighting apparatus shall be readily available when welding or cutting is\nperformed.\n\nK. Precautions shall be taken before applying heat, cutting, or welding on any\npipe or container that has contained a flammable or combustible material.\n\nL. Every oxygen or acetylene bottle shall be (i) stored in a rack constructed\nand designated for the storage of such bottles with their caps in place and (ii)\nsecured when not in use. Such bottles shall not be stored near oil, grease, or\nother flammable material.\n\nM. Every oxygen and acetylene gauge and regulator shall be kept clean and free\nof oil, grease, and other combustible materials.\n\nN. Every belt conveyor shall be equipped with a control switch to automatically\nstop the driving motor of the conveyor in the event that the belt is stopped by\nslipping on the driving pulley as a result of breakage or other accident.\n\nO. The area surrounding every main fan installation or other mine opening shall\nbe kept free from grass, weeds, underbrush, and other combustible materials for\n25 feet in every direction.\n\nP. Every internal combustion engine, except a diesel engine, shall be shut off\nprior to fueling.\n\nHISTORY: Code 1950, \u00a7 45-85.9; 1954, c. 191; 1966, c. 594, \u00a7 45.1-39; 1978, c.\n729; 1994, c. 28, \u00a7 45.1-161.267; 2021, Sp. Sess. I, c. 387.","edition":{"id":1,"name":"2025","slug":"2025","date_created":"2026-06-21 22:39:22","date_modified":"2026-06-21 22:39:22","current":1,"order_by":1,"last_import":null}}