{"formats":[{"name":"JSON","format":"json","url":"\/downloads\/2025\/code-json\/45.2-929.json"},{"name":"Plain Text","format":"text","url":"\/downloads\/2025\/code-text\/45.2-929.txt"},{"name":"XML","format":"xml","url":"\/downloads\/2025\/code-xml\/45.2-929.xml"},{"name":"HTML","format":"html","url":"\/downloads\/2025\/code-html\/45.2-929.html"}],"law_id":84296,"edition_id":1,"section_id":84296,"structure_id":15618,"section_number":"45.2-929","catch_line":" Circuit breakers and switches","history":"Code 1950, \u00a7\u00a7 45-82, 45-82.1, 45-82.3, 45-82.4; 1954, c. 191; 1966, c. 594, \u00a7\u00a7 45.1-78, 45.1-80, 45.1-81; 1978, c. 118; 1979, c. 315; 1993, c. 442; 1994, c. 28, \u00a7 45.1-161.282; 1999, c. 256; 2005, c. 3; 2021, Sp. Sess. I, c. 387.","full_text":"A\n\nAn automatic circuit breaking device or fuse of the correct type and capacity shall be installed so as to protect each piece of electric equipment and power circuit against excessive overload. Wire or another conducting material shall not be used as a substitute for a properly designed fuse, and every circuit breaking device shall be maintained in safe operating condition.B\n\nOperating controls, such as switches, starters, or switch buttons, shall be so installed that they are readily accessible and can be operated without danger of contact with moving or live parts.C\n\nElectric equipment and circuits shall be provided with switches or other controls of safe design, construction, and installation.D\n\nAn insulating mat or other electrically nonconductive material shall be kept in place at each power-control switch and at stationary machinery where a shock hazard exists.E\n\nSuitable warning signs shall be posted conspicuously at every high-voltage installation.F\n\nEvery power wire or cable shall have adequate current-carrying capacity, be guarded from mechanical injury, and be installed in a permanent manner.G\n\nEvery power circuit shall be labeled to indicate the unit or circuit that it controls.H\n\nAll persons shall stay clear of any electrically powered shovel or other similar heavy equipment during an electrical storm.I\n\nEvery device that is installed on or after July 1, 2005, that provides either short circuit protection or protection against overload shall conform to the minimum requirements for protection of electric circuits and equipment of the National Electrical Code in effect at the time of its installation.J\n\nEvery electric conductor installed on or after July 1, 2005, shall be sufficient in size to meet the minimum current-carrying capacity provided for in the National Electrical Code in effect at the time of its installation.K\n\nEvery trailing cable purchased on or after July 1, 2005, shall meet the minimum requirements for ampacity provided in the standards of the Insulated Cable Engineers Association\/National Electrical Manufacturers Association in effect at the time such cable is purchased.","order_by":null,"text":{"0":{"id":302176,"text":"An automatic circuit breaking device or fuse of the correct type and capacity shall be installed so as to protect each piece of electric equipment and power circuit against excessive overload. Wire or another conducting material shall not be used as a substitute for a properly designed fuse, and every circuit breaking device shall be maintained in safe operating condition.","type":"section","prefixes":["A"],"prefix":"A","entire_prefix":"A","prefix_anchor":"A","level":1,"next_prefix":"B"},"1":{"id":302177,"text":"Operating controls, such as switches, starters, or switch buttons, shall be so installed that they are readily accessible and can be operated without danger of contact with moving or live parts.","type":"section","prefixes":["B"],"prefix":"B","entire_prefix":"B","prefix_anchor":"B","level":1,"prior_prefix":"A","next_prefix":"C"},"2":{"id":302178,"text":"Electric equipment and circuits shall be provided with switches or other controls of safe design, construction, and installation.","type":"section","prefixes":["C"],"prefix":"C","entire_prefix":"C","prefix_anchor":"C","level":1,"prior_prefix":"B","next_prefix":"D"},"3":{"id":302179,"text":"An insulating mat or other electrically nonconductive material shall be kept in place at each power-control switch and at stationary machinery where a shock hazard exists.","type":"section","prefixes":["D"],"prefix":"D","entire_prefix":"D","prefix_anchor":"D","level":1,"prior_prefix":"C","next_prefix":"E"},"4":{"id":302180,"text":"Suitable warning signs shall be posted conspicuously at every high-voltage installation.","type":"section","prefixes":["E"],"prefix":"E","entire_prefix":"E","prefix_anchor":"E","level":1,"prior_prefix":"D","next_prefix":"F"},"5":{"id":302181,"text":"Every power wire or cable shall have adequate current-carrying capacity, be guarded from mechanical injury, and be installed in a permanent manner.","type":"section","prefixes":["F"],"prefix":"F","entire_prefix":"F","prefix_anchor":"F","level":1,"prior_prefix":"E","next_prefix":"G"},"6":{"id":302182,"text":"Every power circuit shall be labeled to indicate the unit or circuit that it controls.","type":"section","prefixes":["G"],"prefix":"G","entire_prefix":"G","prefix_anchor":"G","level":1,"prior_prefix":"F","next_prefix":"H"},"7":{"id":302183,"text":"All persons shall stay clear of any electrically powered shovel or other similar heavy equipment during an electrical storm.","type":"section","prefixes":["H"],"prefix":"H","entire_prefix":"H","prefix_anchor":"H","level":1,"prior_prefix":"G","next_prefix":"I"},"8":{"id":302184,"text":"Every device that is installed on or after July 1, 2005, that provides either short circuit protection or protection against overload shall conform to the minimum requirements for protection of electric circuits and equipment of the National Electrical Code in effect at the time of its installation.","type":"section","prefixes":["I"],"prefix":"I","entire_prefix":"I","prefix_anchor":"I","level":1,"prior_prefix":"H","next_prefix":"J"},"9":{"id":302185,"text":"Every electric conductor installed on or after July 1, 2005, shall be sufficient in size to meet the minimum current-carrying capacity provided for in the National Electrical Code in effect at the time of its installation.","type":"section","prefixes":["J"],"prefix":"J","entire_prefix":"J","prefix_anchor":"J","level":1,"prior_prefix":"I","next_prefix":"K"},"10":{"id":302186,"text":"Every trailing cable purchased on or after July 1, 2005, shall meet the minimum requirements for ampacity provided in the standards of the Insulated Cable Engineers Association\/National Electrical Manufacturers Association in effect at the time such cable is purchased.","type":"section","prefixes":["K"],"prefix":"K","entire_prefix":"K","prefix_anchor":"K","level":1,"prior_prefix":"J"}},"ancestry":[{"id":15618,"edition_id":1,"name":"Electricity","identifier":"9","label":"article","depth":5,"order_by":1,"parent_id":13645,"metadata":{},"date_created":"2026-06-26 03:56:59","date_modified":"2026-06-26 03:56:59","permalink":{"id":224087,"object_type":"structure","relational_id":15618,"identifier":"9","token":"45.2\/II\/C\/9\/9","url":"\/45.2\/II\/C\/9\/9\/","edition_id":1,"permalink":0,"preferred":1}},{"id":13645,"edition_id":1,"name":"Requirements Applicable to Surface Coal Mines","identifier":"9","label":"chapter","depth":4,"order_by":1,"parent_id":13539,"metadata":{},"date_created":"2026-06-26 03:45:27","date_modified":"2026-06-26 03:45:27","permalink":{"id":223921,"object_type":"structure","relational_id":13645,"identifier":"9","token":"45.2\/II\/C\/9","url":"\/45.2\/II\/C\/9\/","edition_id":1,"permalink":0,"preferred":1}},{"id":13539,"edition_id":1,"name":"Surface Coal Mines","identifier":"C","label":"part","depth":3,"order_by":1,"parent_id":12985,"metadata":{},"date_created":"2026-06-26 03:45:10","date_modified":"2026-06-26 03:45:10","permalink":{"id":223695,"object_type":"structure","relational_id":13539,"identifier":"C","token":"45.2\/II\/C","url":"\/45.2\/II\/C\/","edition_id":1,"permalink":0,"preferred":1}},{"id":12985,"edition_id":1,"name":"Coal Mining","identifier":"II","label":"subtitle","depth":2,"order_by":1,"parent_id":12713,"metadata":{},"date_created":"2026-06-26 03:44:06","date_modified":"2026-06-26 03:44:06","permalink":{"id":222647,"object_type":"structure","relational_id":12985,"identifier":"II","token":"45.2\/II","url":"\/45.2\/II\/","edition_id":1,"permalink":0,"preferred":1}},{"id":12713,"edition_id":1,"name":"Mines, Minerals, and Energy","identifier":"45.2","label":"title","depth":1,"order_by":1,"parent_id":null,"metadata":{},"date_created":"2026-06-26 03:43:49","date_modified":"2026-06-26 03:43:49","permalink":{"id":222539,"object_type":"structure","relational_id":12713,"identifier":"45.2","token":"45.2","url":"\/45.2\/","edition_id":1,"permalink":0,"preferred":1}}],"structure_contents":[{"id":86325,"structure_id":15618,"section_number":"45.2-926","catch_line":" Overhead high-potential power lines; surface transmission lines; electric wiring in surface buildings","url":"\/45.2-926\/","token":"45.2\/II\/C\/9\/9\/45.2-926","metadata":false},{"id":60182,"structure_id":15618,"section_number":"45.2-927","catch_line":" Transformers","url":"\/45.2-927\/","token":"45.2\/II\/C\/9\/9\/45.2-927","metadata":false},{"id":66784,"structure_id":15618,"section_number":"45.2-928","catch_line":" Grounding","url":"\/45.2-928\/","token":"45.2\/II\/C\/9\/9\/45.2-928","metadata":false},{"id":84296,"structure_id":15618,"section_number":"45.2-929","catch_line":" Circuit breakers and switches","url":"\/45.2-929\/","token":"45.2\/II\/C\/9\/9\/45.2-929","metadata":false},{"id":59647,"structure_id":15618,"section_number":"45.2-930","catch_line":" Electrical trailing cables","url":"\/45.2-930\/","token":"45.2\/II\/C\/9\/9\/45.2-930","metadata":false}],"previous_section":{"id":66784,"structure_id":15618,"section_number":"45.2-928","catch_line":" Grounding","url":"\/45.2-928\/","token":"45.2\/II\/C\/9\/9\/45.2-928","metadata":false},"next_section":{"id":59647,"structure_id":15618,"section_number":"45.2-930","catch_line":" Electrical trailing cables","url":"\/45.2-930\/","token":"45.2\/II\/C\/9\/9\/45.2-930","metadata":false},"metadata":false,"official_url":"https:\/\/law.lis.virginia.gov\/vacode\/45.2-929\/","history_text":"<p>The record of this law\u2019s original creation isn\u2019t available online. It has been modified 8 times. Those modifications are cataloged by \u201cThe Acts of Assembly,\u201d a state publication, by year and chapter. Those modifications that can be read on the General Assembly\u2019s website will be linked accordingly. Those modifications are as follows: in 1954, chapter 191; in 1966, chapter 594; in 1978, chapter 118; in 1979, chapter 315; in 1993, chapter 442; in 1994, chapter <a href=\"https:\/\/legacylis.virginia.gov\/cgi-bin\/legp604.exe?941+ful+CHAP0028\">28<\/a>; in 1999, chapter <a href=\"https:\/\/legacylis.virginia.gov\/cgi-bin\/legp604.exe?991+ful+CHAP0256\">256<\/a>; in 2005, chapter <a href=\"https:\/\/legacylis.virginia.gov\/cgi-bin\/legp604.exe?051+ful+CHAP0003\">3<\/a>.<\/p>","references":false,"refers_to":false,"permalink":{"id":224101,"object_type":"law","relational_id":84296,"identifier":"45.2-929","token":"45.2\/II\/C\/9\/9\/45.2-929","url":"\/45.2-929\/","edition_id":1,"permalink":0,"preferred":1},"url":"\/45.2-929\/","token":"45.2\/II\/C\/9\/9\/45.2-929","dublin_core":{"Title":" Circuit breakers and switches","Type":"Text","Format":"text\/html","Identifier":"\u00a7 45.2-929","Relation":"Code of Virginia"},"html":"\n\t\t\t\t\t\t<section id=\"A\"><p><span class=\"prefix-number\">A.<\/span> An automatic <span class=\"dictionary\">circuit<\/span> breaking device or fuse of the correct type and capacity shall be installed so as to protect each piece of electric equipment and power <span class=\"dictionary\">circuit<\/span> against excessive overload. Wire or another conducting <span class=\"dictionary\">material<\/span> shall not be used as a substitute for a properly designed fuse, and every <span class=\"dictionary\">circuit<\/span> breaking device shall be maintained in safe operating condition. <a id=\"paragraph-302176\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-929\/#A\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"B\"><p><span class=\"prefix-number\">B.<\/span> Operating controls, such as switches, starters, or switch buttons, shall be so installed that they are readily accessible and can be operated without danger of contact with moving or live parts. <a id=\"paragraph-302177\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-929\/#B\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"C\"><p><span class=\"prefix-number\">C.<\/span> Electric equipment and <span class=\"dictionary\">circuits<\/span> shall be provided with switches or other controls of safe design, construction, and installation. <a id=\"paragraph-302178\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-929\/#C\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"D\"><p><span class=\"prefix-number\">D.<\/span> An insulating mat or other electrically nonconductive <span class=\"dictionary\">material<\/span> shall be kept in place at each power-control switch and at stationary machinery where a shock hazard exists. <a id=\"paragraph-302179\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-929\/#D\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"E\"><p><span class=\"prefix-number\">E.<\/span> Suitable warning signs shall be posted conspicuously at every high-voltage installation. <a id=\"paragraph-302180\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-929\/#E\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"F\"><p><span class=\"prefix-number\">F.<\/span> Every power wire or cable shall have adequate current-carrying capacity, be guarded from mechanical injury, and be installed in a permanent manner. <a id=\"paragraph-302181\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-929\/#F\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"G\"><p><span class=\"prefix-number\">G.<\/span> Every power <span class=\"dictionary\">circuit<\/span> shall be labeled to indicate the unit or <span class=\"dictionary\">circuit<\/span> that it controls. <a id=\"paragraph-302182\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-929\/#G\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"H\"><p><span class=\"prefix-number\">H.<\/span> All persons shall <span class=\"dictionary\">stay<\/span> clear of any electrically powered shovel or other similar heavy equipment during an electrical storm. <a id=\"paragraph-302183\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-929\/#H\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"I\"><p><span class=\"prefix-number\">I.<\/span> Every device that is installed on or after July 1, 2005, that provides either short <span class=\"dictionary\">circuit<\/span> protection or protection against overload shall conform to the minimum requirements for protection of electric <span class=\"dictionary\">circuits<\/span> and equipment of the National Electrical Code in effect at the time of its installation. <a id=\"paragraph-302184\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-929\/#I\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"J\"><p><span class=\"prefix-number\">J.<\/span> Every electric conductor installed on or after July 1, 2005, shall be sufficient in size to meet the minimum current-carrying capacity provided for in the National Electrical Code in effect at the time of its installation. <a id=\"paragraph-302185\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-929\/#J\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"K\"><p><span class=\"prefix-number\">K.<\/span> Every trailing cable purchased on or after July 1, 2005, shall meet the minimum requirements for ampacity provided in the standards of the Insulated Cable Engineers Association\/National Electrical Manufacturers Association in effect at the time such cable is purchased. <a id=\"paragraph-302186\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-929\/#K\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>","plain_text":"                                 CODE OF VIRGINIA\n\n CIRCUIT BREAKERS AND SWITCHES (\u00a7 45.2-929)\n\nA. An automatic circuit breaking device or fuse of the correct type and capacity\nshall be installed so as to protect each piece of electric equipment and power\ncircuit against excessive overload. Wire or another conducting material shall\nnot be used as a substitute for a properly designed fuse, and every circuit\nbreaking device shall be maintained in safe operating condition.\n\nB. Operating controls, such as switches, starters, or switch buttons, shall be\nso installed that they are readily accessible and can be operated without danger\nof contact with moving or live parts.\n\nC. Electric equipment and circuits shall be provided with switches or other\ncontrols of safe design, construction, and installation.\n\nD. An insulating mat or other electrically nonconductive material shall be kept\nin place at each power-control switch and at stationary machinery where a shock\nhazard exists.\n\nE. Suitable warning signs shall be posted conspicuously at every high-voltage\ninstallation.\n\nF. Every power wire or cable shall have adequate current-carrying capacity, be\nguarded from mechanical injury, and be installed in a permanent manner.\n\nG. Every power circuit shall be labeled to indicate the unit or circuit that it\ncontrols.\n\nH. All persons shall stay clear of any electrically powered shovel or other\nsimilar heavy equipment during an electrical storm.\n\nI. Every device that is installed on or after July 1, 2005, that provides either\nshort circuit protection or protection against overload shall conform to the\nminimum requirements for protection of electric circuits and equipment of the\nNational Electrical Code in effect at the time of its installation.\n\nJ. Every electric conductor installed on or after July 1, 2005, shall be\nsufficient in size to meet the minimum current-carrying capacity provided for in\nthe National Electrical Code in effect at the time of its installation.\n\nK. Every trailing cable purchased on or after July 1, 2005, shall meet the\nminimum requirements for ampacity provided in the standards of the Insulated\nCable Engineers Association\/National Electrical Manufacturers Association in\neffect at the time such cable is purchased.\n\nHISTORY: Code 1950, \u00a7\u00a7 45-82, 45-82.1, 45-82.3, 45-82.4; 1954, c. 191; 1966,\nc. 594, \u00a7\u00a7 45.1-78, 45.1-80, 45.1-81; 1978, c. 118; 1979, c. 315; 1993, c.\n442; 1994, c. 28, \u00a7 45.1-161.282; 1999, c. 256; 2005, c. 3; 2021, Sp. Sess. I,\nc. 387.","edition":{"id":1,"name":"2025","slug":"2025","date_created":"2026-06-21 22:39:22","date_modified":"2026-06-21 22:39:22","current":1,"order_by":1,"last_import":null}}