{"formats":[{"name":"JSON","format":"json","url":"\/downloads\/2025\/code-json\/45.2-930.json"},{"name":"Plain Text","format":"text","url":"\/downloads\/2025\/code-text\/45.2-930.txt"},{"name":"XML","format":"xml","url":"\/downloads\/2025\/code-xml\/45.2-930.xml"},{"name":"HTML","format":"html","url":"\/downloads\/2025\/code-html\/45.2-930.html"}],"law_id":59647,"edition_id":1,"section_id":59647,"structure_id":15618,"section_number":"45.2-930","catch_line":" Electrical trailing cables","history":"Code 1950, \u00a7 45-82.5; 1954, c. 191; 1966, c. 594, \u00a7 45.1-84; 1978, c. 118; 1993, c. 442; 1994, c. 28, \u00a7 45.1-161.283; 2021, Sp. Sess. I, c. 387.","full_text":"A\n\nEvery trailing cable shall be provided with suitable short-circuit protection and a means of disconnecting power from the cable.\n\t\t\tB Any temporary splice in a trailing cable shall be made in a workmanlike manner and shall be mechanically strong and well-insulated.C\n\nThe number of temporary, unvulcanized splices in a trailing cable shall be limited to one.D\n\nEvery permanent splice in a trailing cable shall be made mechanically strong, with adequate electrical conductivity and flexibility, and shall be effectively insulated and sealed so as to exclude moisture. The finished splice shall be vulcanized or otherwise treated with suitable materials to provide flame-resistant properties and good bonding to the outer jacket.E\n\nEvery trailing cable shall be protected against mechanical injury.","order_by":null,"text":{"0":{"id":218435,"text":"Every trailing cable shall be provided with suitable short-circuit protection and a means of disconnecting power from the cable.\n\t\t\tB Any temporary splice in a trailing cable shall be made in a workmanlike manner and shall be mechanically strong and well-insulated.","type":"section","prefixes":["A"],"prefix":"A","entire_prefix":"A","prefix_anchor":"A","level":1,"next_prefix":"C"},"1":{"id":218436,"text":"The number of temporary, unvulcanized splices in a trailing cable shall be limited to one.","type":"section","prefixes":["C"],"prefix":"C","entire_prefix":"C","prefix_anchor":"C","level":1,"prior_prefix":"A","next_prefix":"D"},"2":{"id":218437,"text":"Every permanent splice in a trailing cable shall be made mechanically strong, with adequate electrical conductivity and flexibility, and shall be effectively insulated and sealed so as to exclude moisture. The finished splice shall be vulcanized or otherwise treated with suitable materials to provide flame-resistant properties and good bonding to the outer jacket.","type":"section","prefixes":["D"],"prefix":"D","entire_prefix":"D","prefix_anchor":"D","level":1,"prior_prefix":"C","next_prefix":"E"},"3":{"id":218438,"text":"Every trailing cable shall be protected against mechanical injury.","type":"section","prefixes":["E"],"prefix":"E","entire_prefix":"E","prefix_anchor":"E","level":1,"prior_prefix":"D"}},"ancestry":[{"id":15618,"edition_id":1,"name":"Electricity","identifier":"9","label":"article","depth":5,"order_by":1,"parent_id":13645,"metadata":{},"date_created":"2026-06-26 03:56:59","date_modified":"2026-06-26 03:56:59","permalink":{"id":224087,"object_type":"structure","relational_id":15618,"identifier":"9","token":"45.2\/II\/C\/9\/9","url":"\/45.2\/II\/C\/9\/9\/","edition_id":1,"permalink":0,"preferred":1}},{"id":13645,"edition_id":1,"name":"Requirements Applicable to Surface Coal Mines","identifier":"9","label":"chapter","depth":4,"order_by":1,"parent_id":13539,"metadata":{},"date_created":"2026-06-26 03:45:27","date_modified":"2026-06-26 03:45:27","permalink":{"id":223921,"object_type":"structure","relational_id":13645,"identifier":"9","token":"45.2\/II\/C\/9","url":"\/45.2\/II\/C\/9\/","edition_id":1,"permalink":0,"preferred":1}},{"id":13539,"edition_id":1,"name":"Surface Coal Mines","identifier":"C","label":"part","depth":3,"order_by":1,"parent_id":12985,"metadata":{},"date_created":"2026-06-26 03:45:10","date_modified":"2026-06-26 03:45:10","permalink":{"id":223695,"object_type":"structure","relational_id":13539,"identifier":"C","token":"45.2\/II\/C","url":"\/45.2\/II\/C\/","edition_id":1,"permalink":0,"preferred":1}},{"id":12985,"edition_id":1,"name":"Coal Mining","identifier":"II","label":"subtitle","depth":2,"order_by":1,"parent_id":12713,"metadata":{},"date_created":"2026-06-26 03:44:06","date_modified":"2026-06-26 03:44:06","permalink":{"id":222647,"object_type":"structure","relational_id":12985,"identifier":"II","token":"45.2\/II","url":"\/45.2\/II\/","edition_id":1,"permalink":0,"preferred":1}},{"id":12713,"edition_id":1,"name":"Mines, Minerals, and Energy","identifier":"45.2","label":"title","depth":1,"order_by":1,"parent_id":null,"metadata":{},"date_created":"2026-06-26 03:43:49","date_modified":"2026-06-26 03:43:49","permalink":{"id":222539,"object_type":"structure","relational_id":12713,"identifier":"45.2","token":"45.2","url":"\/45.2\/","edition_id":1,"permalink":0,"preferred":1}}],"structure_contents":[{"id":86325,"structure_id":15618,"section_number":"45.2-926","catch_line":" Overhead high-potential power lines; surface transmission lines; electric wiring in surface buildings","url":"\/45.2-926\/","token":"45.2\/II\/C\/9\/9\/45.2-926","metadata":false},{"id":60182,"structure_id":15618,"section_number":"45.2-927","catch_line":" Transformers","url":"\/45.2-927\/","token":"45.2\/II\/C\/9\/9\/45.2-927","metadata":false},{"id":66784,"structure_id":15618,"section_number":"45.2-928","catch_line":" Grounding","url":"\/45.2-928\/","token":"45.2\/II\/C\/9\/9\/45.2-928","metadata":false},{"id":84296,"structure_id":15618,"section_number":"45.2-929","catch_line":" Circuit breakers and switches","url":"\/45.2-929\/","token":"45.2\/II\/C\/9\/9\/45.2-929","metadata":false},{"id":59647,"structure_id":15618,"section_number":"45.2-930","catch_line":" Electrical trailing cables","url":"\/45.2-930\/","token":"45.2\/II\/C\/9\/9\/45.2-930","metadata":false}],"previous_section":{"id":84296,"structure_id":15618,"section_number":"45.2-929","catch_line":" Circuit breakers and switches","url":"\/45.2-929\/","token":"45.2\/II\/C\/9\/9\/45.2-929","metadata":false},"metadata":false,"official_url":"https:\/\/law.lis.virginia.gov\/vacode\/45.2-930\/","history_text":"<p>The record of this law\u2019s original creation isn\u2019t available online. It has been modified 5 times. Those modifications are cataloged by \u201cThe Acts of Assembly,\u201d a state publication, by year and chapter. Those modifications that can be read on the General Assembly\u2019s website will be linked accordingly. Those modifications are as follows: in 1954, chapter 191; in 1966, chapter 594; in 1978, chapter 118; in 1993, chapter 442; in 1994, chapter <a href=\"https:\/\/legacylis.virginia.gov\/cgi-bin\/legp604.exe?941+ful+CHAP0028\">28<\/a>.<\/p>","references":false,"refers_to":false,"permalink":{"id":224105,"object_type":"law","relational_id":59647,"identifier":"45.2-930","token":"45.2\/II\/C\/9\/9\/45.2-930","url":"\/45.2-930\/","edition_id":1,"permalink":0,"preferred":1},"url":"\/45.2-930\/","token":"45.2\/II\/C\/9\/9\/45.2-930","dublin_core":{"Title":" Electrical trailing cables","Type":"Text","Format":"text\/html","Identifier":"\u00a7 45.2-930","Relation":"Code of Virginia"},"html":"\n\t\t\t\t\t\t<section id=\"A\"><p><span class=\"prefix-number\">A.<\/span> Every trailing cable shall be provided with suitable short-<span class=\"dictionary\">circuit<\/span> protection and a means of disconnecting power from the cable.\n\t\t\tB Any temporary splice in a trailing cable shall be made in a workmanlike manner and shall be mechanically strong and well-insulated. <a id=\"paragraph-218435\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-930\/#A\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"C\"><p><span class=\"prefix-number\">C.<\/span> The number of temporary, unvulcanized splices in a trailing cable shall be limited to one. <a id=\"paragraph-218436\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-930\/#C\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"D\"><p><span class=\"prefix-number\">D.<\/span> Every permanent splice in a trailing cable shall be made mechanically strong, with adequate electrical conductivity and flexibility, and shall be effectively insulated and <span class=\"dictionary\">sealed<\/span> so as to exclude moisture. The finished splice shall be vulcanized or otherwise treated with suitable <span class=\"dictionary\">materials<\/span> to provide flame-resistant properties and good bonding to the outer jacket. <a id=\"paragraph-218437\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-930\/#D\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>\n\t\t\t\t\t\t<section id=\"E\"><p><span class=\"prefix-number\">E.<\/span> Every trailing cable shall be protected against mechanical injury. <a id=\"paragraph-218438\" class=\"section-permalink\" href=\"https:\/\/vacode.org\/45.2-930\/#E\"><i class=\"fa fa-link\"><\/i><\/a><\/p><\/section>","plain_text":"                                 CODE OF VIRGINIA\n\n ELECTRICAL TRAILING CABLES (\u00a7 45.2-930)\n\nA. Every trailing cable shall be provided with suitable short-circuit protection\nand a means of disconnecting power from the cable.\n\t\t\tB Any temporary splice in a trailing cable shall be made in a workmanlike\nmanner and shall be mechanically strong and well-insulated.\n\nC. The number of temporary, unvulcanized splices in a trailing cable shall be\nlimited to one.\n\nD. Every permanent splice in a trailing cable shall be made mechanically strong,\nwith adequate electrical conductivity and flexibility, and shall be effectively\ninsulated and sealed so as to exclude moisture. The finished splice shall be\nvulcanized or otherwise treated with suitable materials to provide\nflame-resistant properties and good bonding to the outer jacket.\n\nE. Every trailing cable shall be protected against mechanical injury.\n\nHISTORY: Code 1950, \u00a7 45-82.5; 1954, c. 191; 1966, c. 594, \u00a7 45.1-84; 1978, c.\n118; 1993, c. 442; 1994, c. 28, \u00a7 45.1-161.283; 2021, Sp. Sess. I, c. 387.","edition":{"id":1,"name":"2025","slug":"2025","date_created":"2026-06-21 22:39:22","date_modified":"2026-06-21 22:39:22","current":1,"order_by":1,"last_import":null}}