<?xml version="1.0"?>
<law><site_title>Virginia Decoded</site_title><site_url>https://vacode.org</site_url><law_id>57534</law_id><section_number>45.2-717</section_number><catch_line> Unsafe conditions</catch_line><edition url="https://vacode.org/2025/" slug="2025" current="TRUE" last_updated="">2025</edition><structure><unit label="title" level="1" order_by="1" identifier="45.2">Mines, Minerals, and Energy</unit><unit label="subtitle" level="2" order_by="1" identifier="II">Coal Mining</unit><unit label="part" level="3" order_by="1" identifier="B">Underground Coal Mines</unit><unit label="chapter" level="4" order_by="1" identifier="7">Requirements Applicable to Underground Coal Mines; Mine Construction</unit><unit label="article" level="5" order_by="1" identifier="4">Roof, Face, and Rib Control</unit></structure><text>
						<section id="A"><p><span class="prefix-number">A.</span> No person shall work or travel under unsupported roof except to install temporary supports in accordance with the approved roof control plan. Any area inby the breaker line where second mining has been or is being conducted shall be considered unsupported. <a id="paragraph-210787" class="section-permalink" href="https://vacode.org/45.2-717/#A"><i class="fa fa-link"/></a></p></section>
						<section id="B"><p><span class="prefix-number">B.</span> If roof, face, or rib conditions are found to be unsafe, no person shall start any other work in the area where such conditions exist until the conditions have been corrected by taking down loose <span class="dictionary">material</span> or securely supporting the roof, face, or ribs pursuant to subsection B of &#xA7; <a class="law" title=" Examination and testing of roof, face, and ribs" href="/45.2-715/">45.2-715</a>. <a id="paragraph-210788" class="section-permalink" href="https://vacode.org/45.2-717/#B"><i class="fa fa-link"/></a></p></section>
						<section id="C"><p><span class="prefix-number">C.</span> A bar of proper length shall be used to pull down any loose <span class="dictionary">material</span> discovered. <a id="paragraph-210789" class="section-permalink" href="https://vacode.org/45.2-717/#C"><i class="fa fa-link"/></a></p></section></text><history>Code 1950, &#xA7;&#xA7; 45-61, 45-68.1, 45-68.3; 1954, c. 191; 1966, c. 594, &#xA7;&#xA7; 45.1-41, 45.1-42; 1975, c. 520; 1976, c. 598; 1978, c. 118; 1980, c. 338; 1982, c. 234; 1988, c. 577; 1994, c. 28, &#xA7; 45.1-161.118; 1999, c. 256; 2005, c. 3; 2021, Sp. Sess. I, c. 387.</history><metadata></metadata></law>