<?xml version="1.0"?>
<law><site_title>Virginia Decoded</site_title><site_url>https://vacode.org</site_url><law_id>59647</law_id><section_number>45.2-930</section_number><catch_line> Electrical trailing cables</catch_line><edition url="https://vacode.org/2025/" slug="2025" current="TRUE" last_updated="">2025</edition><structure><unit label="title" level="1" order_by="1" identifier="45.2">Mines, Minerals, and Energy</unit><unit label="subtitle" level="2" order_by="1" identifier="II">Coal Mining</unit><unit label="part" level="3" order_by="1" identifier="C">Surface Coal Mines</unit><unit label="chapter" level="4" order_by="1" identifier="9">Requirements Applicable to Surface Coal Mines</unit><unit label="article" level="5" order_by="1" identifier="9">Electricity</unit></structure><text>
						<section id="A"><p><span class="prefix-number">A.</span> Every trailing cable shall be provided with suitable short-<span class="dictionary">circuit</span> protection and a means of disconnecting power from the cable.
			B Any temporary splice in a trailing cable shall be made in a workmanlike manner and shall be mechanically strong and well-insulated. <a id="paragraph-218435" class="section-permalink" href="https://vacode.org/45.2-930/#A"><i class="fa fa-link"/></a></p></section>
						<section id="C"><p><span class="prefix-number">C.</span> The number of temporary, unvulcanized splices in a trailing cable shall be limited to one. <a id="paragraph-218436" class="section-permalink" href="https://vacode.org/45.2-930/#C"><i class="fa fa-link"/></a></p></section>
						<section id="D"><p><span class="prefix-number">D.</span> Every permanent splice in a trailing cable shall be made mechanically strong, with adequate electrical conductivity and flexibility, and shall be effectively insulated and <span class="dictionary">sealed</span> so as to exclude moisture. The finished splice shall be vulcanized or otherwise treated with suitable <span class="dictionary">materials</span> to provide flame-resistant properties and good bonding to the outer jacket. <a id="paragraph-218437" class="section-permalink" href="https://vacode.org/45.2-930/#D"><i class="fa fa-link"/></a></p></section>
						<section id="E"><p><span class="prefix-number">E.</span> Every trailing cable shall be protected against mechanical injury. <a id="paragraph-218438" class="section-permalink" href="https://vacode.org/45.2-930/#E"><i class="fa fa-link"/></a></p></section></text><history>Code 1950, &#xA7; 45-82.5; 1954, c. 191; 1966, c. 594, &#xA7; 45.1-84; 1978, c. 118; 1993, c. 442; 1994, c. 28, &#xA7; 45.1-161.283; 2021, Sp. Sess. I, c. 387.</history><metadata></metadata></law>