§ 45.2-930 Electrical trailing cables

A. Every trailing cable shall be provided with suitable short-circuit protection and a means of disconnecting power from the cable. B Any temporary splice in a trailing cable shall be made in a workmanlike manner and shall be mechanically strong and well-insulated.

C. The number of temporary, unvulcanized splices in a trailing cable shall be limited to one.

D. Every permanent splice in a trailing cable shall be made mechanically strong, with adequate electrical conductivity and flexibility, and shall be effectively insulated and sealed so as to exclude moisture. The finished splice shall be vulcanized or otherwise treated with suitable materials to provide flame-resistant properties and good bonding to the outer jacket.

E. Every trailing cable shall be protected against mechanical injury.

History

The record of this law’s original creation isn’t available online. It has been modified 5 times. Those modifications are cataloged by “The Acts of Assembly,” a state publication, by year and chapter. Those modifications that can be read on the General Assembly’s website will be linked accordingly. Those modifications are as follows: in 1954, chapter 191; in 1966, chapter 594; in 1978, chapter 118; in 1993, chapter 442; in 1994, chapter 28.