§ 40.1-51.19:4 Operations and maintenance
A. A hobby or model boiler must be attended by a person reasonably competent to operate such boiler when in operation. For the purposes of this section, a hobby or model boiler may be considered as not being in operation when all of the following conditions exist:
1. The water level is at least one-third of the water gauge glass;
2. The fire is banked and the draft doors closed or the fire is extinguished; and
3. The boiler pressure is at least twenty pounds per square inch below the lowest safety valve set pressure.
B. All welding performed on hobby or model boilers shall be done by an “R” stamp holder in accordance with the inspection code of the National Board of Boiler and Pressure Vessel Inspectors.
History
This law was first created in 1999. The record of its establishment is cataloged in chapter 335 of that year’s edition of “Acts of Assembly,” the annual state publication listing all changes made to the Code of Virginia in that year. It has been modified 1 time. Those modifications are cataloged by “The Acts of Assembly,” a state publication, by year and chapter. Those modifications that can be read on the General Assembly’s website will be linked accordingly. That modification is as follows: in 2000, chapter 898.
1999, c. 335; 2000, c. 898.